ESWT Wound Therapy
THE FOCUSED PIEZO SHOCKWAVE FOR THE TREATMENT OF WOUNDS IN DIABETIC FOOT SYNDROME
Extracorporeal shockwave therapy (ESWT) is a non-invasive procedure which can stimulate wound healing. Shockwaves are characterized by a high positive pressure amplitude with a very short rise time of a few nanoseconds, followed after a few microseconds by a brief negative pressure amplitude. The pressure then levels out and returns to normal again. The focused shockwaves used in ESWT achieve their peak pressure precisely in the target tissue.
Treating wounds with shockwave therapy
For a long time the biological mechanism of action by which shockwaves improve wound healing were not understood; however, the effects have been precisely described. Research findings have been confirmed by clinical results which showed significant improvements in wound healing.
In recent years, numerous scientific studies and publications, some of which also used focused piezo shockwaves, have described the mechanism of action by which ESWT stimulates wound healing. Basically, ESWT is a strong, targeted, mechanical stimulus which promotes biological self-healing processes. On closer investigation this generalized statement describes a host of complex shockwave effects. Mechanical stimuli affect many cellular functions in living tissue including cell growth, cell differentiation, cell migration, protein synthesis, physiologic apoptosis and tissue necrosis. Extracorporeal shockwaves act as mechanical stressors and induce biochemical changes in living tissue which, on a molecular level, ultimately affect the gene expression of cells; when shockwaves are applied selectively they can elicit certain tissue reactions. This process is referred to as mechanotransduction.
Mechanisms of action and effects of ESWT described in the literature:
- Neovascularization
- Induced release of growth factors such as TGF-ß1, VEGF
- Stimulation of fibroblast proliferation
- Stimulation of mesenchymal stem cell migration
- Antibacterial effect
- Stimulation of local blood flow and suppression of pro-inflammatory processes
Administering ESWT to treat wounds
SIMPLE AND EFFECTIVE
Wound treatments are well tolerated by patients and ESWT application is uncomplicated. Sedation or anesthesia is generally not required. To achieve optimal coupling of the shockwave it is important to prevent air pockets. As with ultrasound applications, there should be no air pockets between the therapy source and the target tissue.
The most important treatment steps:
The most important treatment steps:
- Fill the therapy source with fresh shockwave gel (at least 1x daily)
- Insert the gel pad into the therapy source, ensuring that there are no air pockets
- Plug in the therapy source, switch on the unit, select the frequency and intensity setting
- Clean the wound, carry out wound debridement if necessary
- Fill the wound with sterile hydrogel suitable for wounds
- Cover the wound with sterile foil, again making sure there are no air pockets
- Clean the gel pad again where necessary (use disinfectants if necessary)
- Apply shockwave gel (to the gel pad or alternatively to the foil on the patient)
- Place the gel pad on the patient, ensuring there are no air pockets. Administer the shockwaves. During shockwave application, move the therapy source slowly and evenly across the wound and the edges of the wound
- End the application after administering the planned number of shockwaves
- Remove the foil and clean the wound. Wound care should be done in accordance with your own standards of care
Depending on the progress of wound healing, administer shockwaves once a week until the end of therapy.
- Fill the therapy source with fresh shockwave gel (at least 1x daily)
- Insert the gel pad into the therapy source, ensuring that there are no air pockets
- Plug in the therapy source, switch on the unit, select the frequency and intensity setting
- Clean the wound, carry out wound debridement if necessary
- Fill the wound with sterile hydrogel suitable for wounds
- Cover the wound with sterile foil, again making sure there are no air pockets
- Clean the gel pad again where necessary (use disinfectants if necessary)
9. Place the gel pad on the patient, ensuring there are no air pockets. Administer the shockwaves. During shockwave application, move the therapy source slowly and evenly across the wound and the edges of the wound
10. End the application after administering the planned number of shockwaves
11. Remove the foil and clean the wound. Wound care should be done in accordance with your own standards of care
Depending on the progress of wound healing, administer shockwaves once a week until the end of therapy.
TECHNOLOGY OF ESWT WOUND THERAPY
UNIQUE IN WOUND THERAPY – THE USE OF LINEAR FOCUSED SHOCKWAVES
Richard Wolf GmbH and ELvation Medical GmbH have developed a new and unique technology: a linear, focused shockwave. The aim was to create a shockwave that could be applied much more uniformly and effectively compared to conventional point-focused shockwaves. Gel pads are used to adjust the penetration depth to between 0 and 20 mm, ensuring that the acoustic field is optimally adapted to the respective dermatological application.
The PiezoWave² DERM
The focused piezo shockwave to treat wounds
Standard accessories:
Therapy source FBL10x5G2 20 mm for the treatment of chronic diabetic foot syndrome
Gel pads
1 bottle of ESWT contact gel, 250 ml
Foot switch
Cart
The tablet PC is not part of the unit.
Technical specifications
:
External power supply: 220–240 VAC / 50–60 Hz
Noise level: 65 dB(A)
Classification: 93/42 EEC class IIb product
Technical specifications for the therapy source
:
Energy flux density: 0.018–0.160 mJ/mm²
Intensity levels: 20 levels
Maximum penetration depth: 20mm
Foot activation, hand activation
Maintenance
The unit requires very little maintenance. To maximize your product’s lifespan, we recommend the following:
Control unit
In the EU, an annual safety inspection is mandatory. The safety inspection should be combined with a functional check carried out by a maintenance engineer.
Therapy source
The therapy source has a guaranteed lifespan of 5 million shockwave pulses and/or 2 years. A functional check carried out by a maintenance engineer is recommended at the end of this period.
The PiezoWave² DERM
The focused piezo shockwave to treat wounds
Standard accessories:
Therapy source FBL10x5G2 20 mm for the treatment of chronic diabetic foot syndrome
Gel pads
1 bottle of ESWT contact gel, 250 ml
Foot switch
Cart
The tablet PC is not part of the unit.
Technical specifications
:
External power supply: 220–240 VAC / 50–60 Hz
Noise level: 65 dB(A)
Classification: 93/42 EEC class IIb product
Technical specifications for the therapy source
:
Energy flux density: 0.018–0.160 mJ/mm²
Intensity levels: 20 levels
Maximum penetration depth: 20mm
Foot activation, hand activation
Maintenance
The unit requires very little maintenance. To maximize your product’s lifespan, we recommend the following:
Control unit
In the EU, an annual safety inspection is mandatory. The safety inspection should be combined with a functional check carried out by a maintenance engineer.
Therapy source
The therapy source has a guaranteed lifespan of 5 million shockwave pulses and/or 2 years. A functional check carried out by a maintenance engineer is recommended at the end of this period.
ELvation Medical Worldwide − Region Selector
You are visiting the website of the following region:
Rest of World
Please confirm if this is your desired region to ensure we provide you with the most relevant information. You can change your region selection anytime via the website menu.
The information given on this website is valid for the area of the European Union (CE area) and is intended for healthcare professionals only: it may contain information on products and indications that may not be available in all countries.
Is this not the region you were looking for? Select the right region for you: